Home > Company News > How to use glass plate liquid level gauge?
Company News
1. Check that the installation is correct and the level gauge is intact.
2. If there are multiple valves from the equipment to the level gauge, first open the valve other than the one provided by the level gauge or the one closest to the level gauge.
3. Slowly open the upper needle type air valve until it is fully open.
4. Slowly open the lower liquid phase needle valve until it is fully open.
5. Flush the liquid level gauge and eliminate the possibility of pressure pipe plugging during flushing.
Note: when opening the valve and flushing operation, the valve shall be opened slowly to prevent blockage caused by the action of leakage proof device of liquid level gauge.
If you are interested in the glass plate level gauge, clear glass plate, liquid level gauge glass plate or need to consult, please click on our online customer service, or call us.
Pan Chao, customized different quality specifications of the glass.
Pan Chao special industrial glass, tailored for your different quality of the glass.
Welcome sending your inquiry: Phone/WhatsApp : 86 13343800331 Email: sales@panchaoglass.com
- Sand Water Filter/Water treatment plants
- Automatic Doypack Seal Machine (insert and sealing machine)
- IPX3/IPX4 Hand-held Water Spray Nozzle Test Device IEC 60529
- IPX5,IPX6 Jet Nozzle of IEC 60529, Brass material
- Adjustable and multifunctional Spring Impact Hammer IK01-IK07 Level Tester
- Test probe 43 IEC 61032-Probe 43-Figure 17 Jusdtest
- IEC61032-Probe 41-Figure 16 Test probe 41
- IEC61032-Probe 32-Figure 15 Test probe 32
- Test probe 31 IEC61032-Probe 31-Figure 14
- Jointed Child Finger Probes IEC 61032-Probe 19-Figure 13 R 2.5±0.05 mm
- Test probe 18 of IEC 61032 R4.3mm Jointed Child Finger Probes
- Digital recorder for Lugeon testing